Supported devices

The same extraction engine serves the web app, REST API, CLI, and AI skill.

Device Manufacturer BiomAI testing and optimization
Aladdin Topcon Yes
Anterion Heidelberg Yes
Argos Alcon Yes
Eyestar 900 Haag-Streit Yes
IOLMaster 700 ZEISS Yes
Lenstar LS 900 Haag-Streit Yes
MS-39 CSO Recognized device; not in the optimized set
OA-2000 Tomey Yes
Pentacam AXL OCULUS Yes

Testing does not guarantee correct extraction. Report layout, software version, and image quality can affect results. Other reports may be recognized as Other; review their results carefully. Use the schema enum values when creating JSON.

BiomAI reads device and examination details, patient context, and the core measurements for each eye: AL, ACD, anterior K1/K2 and axes, WTW, LT, CCT, lens status, refractive-surgery status, and keratometric index.

BiomAI also extracts explicitly printed posterior (PK1/PK2) and total (TK1/TK2) keratometry from IOLMaster700 only, including posterior values on later provided pages. For each eye, BiomAI keeps a PK or TK pair only if it passes all three checks:

  • Both powers and both axes are present.
  • Powers are in the correct order by magnitude.
  • Axes differ by exactly 90°.

If a check fails, BiomAI clears all four fields of that pair. Automatic PK/TK output is cleared for other identified devices. PK and TK share posterior_keratometry.pk_device_name. This source is separate from the main biometer. You can also provide these values in JSON under extra_data. See the response schema. Free-text notes are not extracted. The web app supports manual PK and TK entry. TK is allowed only when the shared PK / TK device is IOLMaster700. This restriction is also enforced on JSON input.

Missing, unreadable, or unavailable measurements may appear as null. Check the source before interpreting an empty field. Schema validation checks format and ranges, not clinical correctness.

  • Upload PDF, JPG/JPEG, PNG, GIF, or BMP. JSON is also accepted for validation and re-upload.
  • Use a readable report with the patient, eye labels, units, and measurement headings visible. For photos, avoid glare, blur, and cropping through values.
  • Check the selected examination and laterality when the report contains more than one set of measurements.

Renaming an unsupported file does not convert it to a supported format. See Troubleshooting for upload failures and missing measurements.